Where:
Q1, Q2, Q3 – volume flows in (m3/s) or (m3/h),
ρ1, ρ2, ρ3 – density in (kg/m3),
p1, p2, p3 – pressure in (bar), recommended in (bar abs).
Indexs:
1 - transmission fluid at the entrance to ejector,
2 - suctioned fluid at the entrance to ejector,
3 - mixture of driving fluid and suctioned fluid on exit ejector.
When ordering ejektora should include the following information:
Ejector dimensions by the flow
| Size | Max flow | DN attachments | Size (mm) | ||||
| - | Q3 (kg/h) | A | B | C | a | b | c |
| 1 | 1200 | 20 | 20 | 20 | 40 | 80 | 150 |
| 2 | 3500 | 25 | 20 | 32 | 60 | 85 | 370 |
| 3 | 6000 | 32 | 25 | 40 | 65 | 100 | 350 |
| 4 | 12000 | 40 | 32 | 50 | 70 | 115 | 410 |
| 5 | 24000 | 50 | 40 | 65 | 80 | 125 | 480 |
| 6 | 32000 | 65 | 40 | 65 | 80 | 125 | 480 |
| 7 | 40000 | 65 | 50 | 80 | 80 | 125 | 530 |
| 8 | 70000 | 80 | 65 | 100 | 115 | 135 | 730 |
| 9 | 100000 | 100 | 80 | 125 | 150 | 165 | 950 |